Building resource C:\Active_NOW\AHU (generic)\multi24 IEC 61131-3 code\$ENV$\multi24\multi24.MAK.

Executing Pre-Build-Steps:

Delete C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\$GEN$\multi24\$TASK00$.CRD

Delete C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\$GEN$\multi24\BuildLog.txt

Delete C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\$GEN$\multi24\FB_HEATING_VALVE_POSITION_CALCULATION.INC

Delete C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\$GEN$\multi24\FB_HEATING_VALVE_POSITION_CALCULATION.OBJ

Delete C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\$GEN$\multi24\FB_LIMITS_VERIFICATION.INC

Delete C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\$GEN$\multi24\FB_LIMITS_VERIFICATION.OBJ

Delete C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\$GEN$\multi24\FB_REGISTERS_DISPLAY_PROGRAM_SYNC.INC

Delete C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\$GEN$\multi24\FB_REGISTERS_DISPLAY_PROGRAM_SYNC.OBJ

Delete C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\$GEN$\multi24\FB_REGISTERS_DISPLAY_SET.INC

Delete C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\$GEN$\multi24\FB_REGISTERS_DISPLAY_SET.OBJ

Delete C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\$GEN$\multi24\FB_REGISTERS_DISPLAY_SYNC.INC

Delete C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\$GEN$\multi24\FB_REGISTERS_DISPLAY_SYNC.OBJ

Delete C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\$GEN$\multi24\F_FACTORY_DEFAULT_VALUE.INC

Delete C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\$GEN$\multi24\F_FACTORY_DEFAULT_VALUE.OBJ

Delete C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\$GEN$\multi24\F_HRU_EFFECTIVENESS_CALCULATION.INC

Delete C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\$GEN$\multi24\F_HRU_EFFECTIVENESS_CALCULATION.OBJ

Delete C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\$GEN$\multi24\IOs.CRD

Delete C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\$GEN$\multi24\IOs.INC

Delete C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\$GEN$\multi24\IOs.OBJ

Delete C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\$GEN$\multi24\main_AHU.CRD

Delete C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\$GEN$\multi24\main_AHU.INC

Delete C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\$GEN$\multi24\main_AHU.OBJ

Delete C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\$GEN$\multi24\MULTI24.bpd

Delete C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\$GEN$\multi24\multi24.PCD

Delete C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\$GEN$\multi24\Parameters_and_Values_Synchronisation.CRD

Delete C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\$GEN$\multi24\Parameters_and_Values_Synchronisation.INC

Delete C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\$GEN$\multi24\Parameters_and_Values_Synchronisation.OBJ

Delete C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\$GEN$\multi24\pceData.txt

Delete C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\$GEN$\multi24\pceSegs.txt

Delete C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\$GEN$\multi24\pceVars.txt

Delete C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\$GEN$\multi24\pceVars.txt.xml

Delete C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\$GEN$\multi24\PROJECT_VARIABLES.INC

Delete C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\$GEN$\multi24\PROJECT_VARIABLES.OBJ

Delete C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\$GEN$\multi24\Startup_Sequence.CRD

Delete C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\$GEN$\multi24\Startup_Sequence.INC

Delete C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\$GEN$\multi24\Startup_Sequence.OBJ

Delete C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\$GEN$\multi24\USERTYPE.INC



Creating dependency list(s): 

C:\Active_NOW\AHU (generic)\multi24 IEC 61131-3 code\Startup_Sequence.POE

C:\Active_NOW\AHU (generic)\multi24 IEC 61131-3 code\main_AHU.POE

C:\Active_NOW\AHU (generic)\multi24 IEC 61131-3 code\Parameters_and_Values_Synchronisation.POE

C:\Active_NOW\AHU (generic)\multi24 IEC 61131-3 code\IOs.POE



Creating dependency list(s): 

C:\Active_NOW\AHU (generic)\multi24 IEC 61131-3 code\PROJECT_VARIABLES.POE



Compiling ...



Performing syntax check on file(s): 

C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\USERTYPE.typ

0 error(s), 0 warning(s) - C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\USERTYPE.typ.





Creating prototype(s): 

C:\Active_NOW\AHU (generic)\multi24 IEC 61131-3 code\PROJECT_VARIABLES.POE



Creating include file(s): 

C:\Active_NOW\AHU (generic)\multi24 IEC 61131-3 code\PROJECT_VARIABLES.POE



Compiling file(s): 

C:\Active_NOW\AHU (generic)\multi24 IEC 61131-3 code\PROJECT_VARIABLES.POE

0 error(s), 0 warning(s) - C:\Active_NOW\AHU (generic)\multi24 IEC 61131-3 code\PROJECT_VARIABLES.POE.





Creating prototype(s): 

C:\Active_NOW\AHU (generic)\multi24 IEC 61131-3 code\Startup_Sequence.POE

C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\FUNCTIONBLOCKS\FB_LIMITS_VERIFICATION.POE

C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\FUNCTIONBLOCKS\F_FACTORY_DEFAULT_VALUE.POE

C:\Active_NOW\AHU (generic)\multi24 IEC 61131-3 code\main_AHU.POE

C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\FUNCTIONBLOCKS\FB_HEATING_VALVE_POSITION_CALCULATION.POE

C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\FUNCTIONBLOCKS\F_HRU_EFFECTIVENESS_CALCULATION.POE

C:\Active_NOW\AHU (generic)\multi24 IEC 61131-3 code\Parameters_and_Values_Synchronisation.POE

C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\FUNCTIONBLOCKS\FB_REGISTERS_DISPLAY_PROGRAM_SYNC.POE

C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\FUNCTIONBLOCKS\FB_REGISTERS_DISPLAY_SYNC.POE

C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\FUNCTIONBLOCKS\FB_REGISTERS_DISPLAY_SET.POE

C:\Active_NOW\AHU (generic)\multi24 IEC 61131-3 code\IOs.POE



Creating include file(s): 

C:\Active_NOW\AHU (generic)\multi24 IEC 61131-3 code\Startup_Sequence.POE

C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\FUNCTIONBLOCKS\FB_LIMITS_VERIFICATION.POE

C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\FUNCTIONBLOCKS\F_FACTORY_DEFAULT_VALUE.POE

C:\Active_NOW\AHU (generic)\multi24 IEC 61131-3 code\main_AHU.POE

C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\FUNCTIONBLOCKS\FB_HEATING_VALVE_POSITION_CALCULATION.POE

C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\FUNCTIONBLOCKS\F_HRU_EFFECTIVENESS_CALCULATION.POE

C:\Active_NOW\AHU (generic)\multi24 IEC 61131-3 code\Parameters_and_Values_Synchronisation.POE

C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\FUNCTIONBLOCKS\FB_REGISTERS_DISPLAY_PROGRAM_SYNC.POE

C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\FUNCTIONBLOCKS\FB_REGISTERS_DISPLAY_SYNC.POE

C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\FUNCTIONBLOCKS\FB_REGISTERS_DISPLAY_SET.POE

C:\Active_NOW\AHU (generic)\multi24 IEC 61131-3 code\IOs.POE



Compiling file(s): 

C:\Active_NOW\AHU (generic)\multi24 IEC 61131-3 code\Startup_Sequence.POE

0 error(s), 0 warning(s) - C:\Active_NOW\AHU (generic)\multi24 IEC 61131-3 code\Startup_Sequence.POE.



C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\FUNCTIONBLOCKS\FB_LIMITS_VERIFICATION.POE

0 error(s), 0 warning(s) - C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\FUNCTIONBLOCKS\FB_LIMITS_VERIFICATION.POE.



C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\FUNCTIONBLOCKS\F_FACTORY_DEFAULT_VALUE.POE

0 error(s), 0 warning(s) - C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\FUNCTIONBLOCKS\F_FACTORY_DEFAULT_VALUE.POE.



C:\Active_NOW\AHU (generic)\multi24 IEC 61131-3 code\main_AHU.POE

0 error(s), 0 warning(s) - C:\Active_NOW\AHU (generic)\multi24 IEC 61131-3 code\main_AHU.POE.



C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\FUNCTIONBLOCKS\FB_HEATING_VALVE_POSITION_CALCULATION.POE

0 error(s), 0 warning(s) - C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\FUNCTIONBLOCKS\FB_HEATING_VALVE_POSITION_CALCULATION.POE.



C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\FUNCTIONBLOCKS\F_HRU_EFFECTIVENESS_CALCULATION.POE

0 error(s), 0 warning(s) - C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\FUNCTIONBLOCKS\F_HRU_EFFECTIVENESS_CALCULATION.POE.



C:\Active_NOW\AHU (generic)\multi24 IEC 61131-3 code\Parameters_and_Values_Synchronisation.POE

0 error(s), 0 warning(s) - C:\Active_NOW\AHU (generic)\multi24 IEC 61131-3 code\Parameters_and_Values_Synchronisation.POE.



C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\FUNCTIONBLOCKS\FB_REGISTERS_DISPLAY_PROGRAM_SYNC.POE

0 error(s), 0 warning(s) - C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\FUNCTIONBLOCKS\FB_REGISTERS_DISPLAY_PROGRAM_SYNC.POE.



C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\FUNCTIONBLOCKS\FB_REGISTERS_DISPLAY_SYNC.POE

0 error(s), 0 warning(s) - C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\FUNCTIONBLOCKS\FB_REGISTERS_DISPLAY_SYNC.POE.



C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\FUNCTIONBLOCKS\FB_REGISTERS_DISPLAY_SET.POE

0 error(s), 0 warning(s) - C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\FUNCTIONBLOCKS\FB_REGISTERS_DISPLAY_SET.POE.



C:\Active_NOW\AHU (generic)\multi24 IEC 61131-3 code\IOs.POE

0 error(s), 0 warning(s) - C:\Active_NOW\AHU (generic)\multi24 IEC 61131-3 code\IOs.POE.





Linking ...

Linking resource globals ...

Linking: C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\$GEN$\multi24\PROJECT_VARIABLES.OBJ.

Linking task STARTUP_SEQUENCE ...

Linking: C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\$GEN$\multi24\Startup_Sequence.OBJ.

Linking: SETINPUTTYPEF.

Linking: SETANALOGOUTPUTF.

Linking: SETDIGITALOUTPUTF.

Linking: GETFIRMWAREVERSIONF.

Linking: SETNAMEF.

Linking: GETREGISTERF.

Linking: C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\$GEN$\multi24\F_FACTORY_DEFAULT_VALUE.OBJ.

Linking: MODBUSREGISTERSFB.

Linking: C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\$GEN$\multi24\FB_LIMITS_VERIFICATION.OBJ.

Linking task MAIN_AHU ...

Linking: C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\$GEN$\multi24\main_AHU.OBJ.

Linking: DINT_TO_TIME.

Linking: C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\$GEN$\multi24\F_HRU_EFFECTIVENESS_CALCULATION.OBJ.

Linking: TON.

Linking: TON.

Linking: TON.

Linking: TON.

Linking: PIDFB.

Linking: PIDFB.

Linking: PIDFB.

Linking: C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\$GEN$\multi24\FB_HEATING_VALVE_POSITION_CALCULATION.OBJ.

Linking task PARAMETERS_AND_VALUES_SYNCHRONISATION ...

Linking: C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\$GEN$\multi24\Parameters_and_Values_Synchronisation.OBJ.

Linking: SETREGISTERF.

Linking: SAVEREGISTERSF.

Linking: MODBUSREGISTERSFB.

Linking: C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\$GEN$\multi24\FB_REGISTERS_DISPLAY_PROGRAM_SYNC.OBJ.

Linking: GETMODBUSTICKF.

Linking: SETDISPLAYPOINTVALUEF.

Linking: SETREGISTERF.

Linking: GETDISPLAYPOINTVALUEF.

Linking: GETREGISTERF.

Linking: C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\$GEN$\multi24\FB_REGISTERS_DISPLAY_SYNC.OBJ.

Linking: GETDISPLAYPOINTVALUEF.

Linking: GETREGISTERF.

Linking: SETREGISTERF.

Linking: SETDISPLAYPOINTVALUEF.

Linking: C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\$GEN$\multi24\FB_REGISTERS_DISPLAY_SET.OBJ.

Linking: SETDISPLAYPOINTVALUEF.

Linking: SETREGISTERF.

Linking: C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\$GEN$\multi24\FB_LIMITS_VERIFICATION.OBJ.

Linking task IOS ...

Linking: C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\$GEN$\multi24\IOs.OBJ.

Linking: GETNTC10MEASUREMENTF.

Linking: GETVOLTAGEMEASUREMENTF.

Linking: GETPT1000MEASUREMENTF.

Linking: GETANALOGINPUTF.

Linking: SETDIGITALOUTPUTF.

Linking: SETANALOGOUTPUTF.

Linking resource: MULTI24 ...

Linking: C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\$GEN$\multi24\$TASK00$.CRD.

Linking: C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\$GEN$\multi24\Startup_Sequence.CRD.

Linking: C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\$GEN$\multi24\main_AHU.CRD.

Linking: C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\$GEN$\multi24\Parameters_and_Values_Synchronisation.CRD.

Linking: C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\$GEN$\multi24\IOs.CRD.

Code size in bytes: 30583.

Number of segments: 149.

0 error(s), 0 warning(s) - C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\$GEN$\multi24\multi24.PCD.



VARTAB32: 46 variables added in 1 segments (2857 bytes)
Executing Post-Build-Steps:

padtrtpsTS610.exe "multi24.M24IEC" -pcd="C:\ACTIVE_NOW\AHU (GENERIC)\MULTI24 IEC 61131-3 CODE\$GEN$\multi24\multi24.PCD" -mak="C:\Active_NOW\AHU (generic)\multi24 IEC 61131-3 code\$ENV$\multi24\multi24.MAK"

Total:
0 error(s) 0 warning(s)